When attempting to change or update the Primary Datastore for a cluster in SDDC Manager, the Update Primary Datastore option in the UI is disabled or greyed out with the following message:
"This operation is not allowed because this cluster was imported."
This issue occurs specifically on clusters brought into SDDC Manager via Brownfield import in a VCF 9.1 environment.
VMware SDDC Manager 9.1
This behavior is by design.
SDDC Manager disables direct UI management workflows for brownfield-imported clusters to prevent unintentional control plane configuration drift or unvalidated metadata modifications.
While the UI action is restricted by design, updating the Primary Datastore for an imported cluster is supported via the SDDC Manager domainInventory REST API.
Follow the standard procedure outlined in KB 452458 to update the SDDC Manager control plane metadata.