When deploying an NSX Edge cluster via SDDC Manager, the validation process may fail with an error indicating a subnet mismatch between the Tunnel Endpoint (TEP) IP and the TEP Gateway IP.
This article provides the steps to identify and resolve this configuration error.
Symptoms:
The NSX Edge cluster deployment fails during the validation phase with the following error: ECM_EDGE_IPS_NOT_IN_SAME_SUBNET Validation that IPs are in same subnet failed. Edge node's TEP IP <IP_ADDRESS>/<MASK> and TEP gateway IP <IP_ADDRESS> are not in the same subnet.
VMware NSX
VMware Cloud Foundation (VCF)
This error occurs when the TEP IP address and the TEP Gateway IP address assigned to the Edge node are not configured within the same subnet. SDDC Manager enforces validation to ensure connectivity requirements are met.