#PF Exception 14 in world #######:bootstrap IP 0x############ addr 0x############
CpuSchedIdleBalanceOnReadyCpuSchedQueueAddIntCpuSchedQueueAddCpuSchedVcpuMakeReadyCpuSched_AddSched_AddWorld_NewSysWorldSchedCpuSched_LateInitSched_LateInitSysInitTable_StartInitVMKernelLegacyBootVMKernelBootVMKernel
VMware ESX 9.x
This issue occurs on certain host platforms when Sub-NUMA Clustering (SNC) is enabled and the CPU topology data provided by the ACPI BIOS is not presented in the sequence expected by ESX 9.x.
When ESX 9.x processes this data during early boot initialization, a memory mapping error occurs within the CPU scheduler's topology handling logic, resulting in an unmapped memory access and a subsequent Page Fault (#PF) crash.
This is a known issue affecting ESX 9.x. Broadcom Engineering is currently working on a resolution. This KB article will be updated once a fix is available.
Workaround:
Disable Sub-NUMA Clustering (SNC)