CA 7: Resolving CA-7.022 LOGON FORMAT INCORRECT During RECONFIG
search cancel

CA 7: Resolving CA-7.022 LOGON FORMAT INCORRECT During RECONFIG

book

Article ID: 452837

calendar_today

Updated On:

Products

CA 7 Workload Automation

Issue/Introduction

When attempting to execute a RECONFIG command via the console, the following error message appears in the SYSLOG:

CA-7.022 - LOGON FORMAT INCORRECT AT CONSOLE

This indicates that the CA 7 environment requires a logged-on session to be established before the console can successfully process the RECONFIG command.

Resolution

To resolve this and ensure the command is processed correctly, follow this two-step sequence:

1. Log on to CA 7: Enter the following command to establish your session: 

          F CA7ONL2,/LOGON <userid>

2. Execute the Command: Wait approximately 5 seconds for the session to initialize, then enter:

       F CA7ONL2,IAS,FUNC=RECONFIG

 