ESXi hosts utilizing any network adapters may experience intermittent or partial Link Aggregation Control Protocol (LACP) negotiation failures on specific physical uplinks. While the physical link state appears as Up, the port fails to bundle correctly within a Link Aggregation Group (LAG).
Symptoms include:
AGG,SYN,COL,DIST (Bundled).Tx) but fails to receive responses (Rx) reliably.
The root cause is typically a hardware-level receiver fault isolated to a specific port on the network adapter, or a failure of the physical SFP/transceiver and associated fiber cabling.
While symptoms like LACPDU asymmetry can sometimes be associated with firmware errata, the fault is isolated to hardware when the issue persists after updating to known-stable driver/firmware baselines and after normalizing all software configurations.
Follow these validated steps to isolate and resolve the physical layer failure:
Verify LACP Statistics: Execute the following command in the ESXi Shell to confirm LACPDU asymmetry:
localcli network vswitch dvs vmware lacp stats getIdentify if Rx LACPDUs remain static or significantly lower than Tx LACPDUs.
Rule out Software/Firmware Variables: Ensure the affected host is running the latest recommended driver and firmware for the vmnic using the Broadcom Compatibility Guide: https://compatibilityguide.broadcom.com/
Physical Layer Isolation: If the issue is isolated to a single port while other ports on the same card function correctly:
Hardware Replacement: If symptoms persist after swapping cables/SFPs, replace the physical SFP and fiber cable associated with the faulty vmnic. In many cases, a hardware-level investigation by the vendor (e.g., HPE) may be required to authorize an adapter replacement.
To speak with a customer representative or a Support Engineer see Contact Support.