When utilizing the BOSS-N1 Monolithic HBA with VMware vSphere ESXi 9.0, hosts may experience storage visibility issues.
partedUtil operations (e.g., getptbl) fail to return valid partition information.
vSphere ESX 9.0
The issue is caused by a firmware incompatibility between the BOSS-N1 Monolithic HBA and VMware vSphere ESXi 9.0.
Incompatible firmware prevents the host from establishing proper communication with the storage controller, resulting in failed storage operations and
failures during update pre-checks, inability to retrieve partition information, or missing local datastores.
To resolve this issue, verify and update the HBA firmware to a version validated by the hardware vendor and the Broadcom Hardware Compatibility List (HCL).
esxcli storage core adapter listesxcli storage core adapter rescan --all