How to identify VID/DID/SVID/SSID for ESX devices
search cancel

How to identify VID/DID/SVID/SSID for ESX devices

book

Article ID: 452030

calendar_today

Updated On:

Products

VMware vSphere ESXi

Issue/Introduction

This article explains how to identify VID/DID/SVID/SSID for ESX devices.

Environment

VMware vSphere ESXi

Resolution

esxcli hardware pci list shows VID/DID/SVID/SSID of each devices.

# esxcli hardware pci list
:::
0000:00:14.0
   Address: 0000:00:14.0
   Segment: 0x0000
   Bus: 0x00
   Slot: 0x14
   Function: 0x0
   Vendor Name: Intel Corporation
   Device Name: Emmitsburg (C740 Family) USB 3.2 Gen 1 xHCI Controller
   Configured Owner: VMkernel
   Current Owner: VMkernel
   Vendor ID: 0x8086      #<- VID
   Device ID: 0x1bcd      #<- DID
   SubVendor ID: 0x1028   #<- SVID
   SubDevice ID: 0x0a6c   #<- SSID
   Device Class: 0x0c03
   Device Class Name: USB controller
   Programming Interface: 0x30
   Revision ID: 0x11
   Interrupt Line: 0xff
   IRQ: 255
   Interrupt Vector: 0x35
   PCI Pin: 0x00
   Spawned Bus: 0x00
   Flags: 0x3001
   Module ID: 61
   Module Name: vmkusb
   Chassis: 0
   Physical Slot: -1
   Slot Description: 
   Device Layer Bus Address: p0000:00:14.0
   Passthru Capable: false
   Parent Device Address: 
   Dependent Device Address: 
   Reset Method: None
   FPT Sharable: false
   NUMA Node: 0
   Hardware Label: 
   Virtual Function: