RVtools times out while running on vCenters in linked mode. However, the RVtools events do not fail on all vCenters except a few in the Environment. (Intermittent)
You will not observe errors in envoy-sidecar, as envoy-sidecar service is not the cause as in https://knowledge.broadcom.com/external/article/384498
vCenter versions 8.0 U3h and higher have been fixed with the issue as in the KB 384498.
vCenter 8.0 U3h and higher
Dell RVtools
RVtools timeout period is lower than the environment's requirement.
Engage with Dell Support to increase the timed-out period on RV tools.
Workaround; (This is temporary fix for ongoing task of RVtools. However, continuous failure in every run of RVtools will be observed.)
- Restart envoy-sidecar service on vCenter to refresh the Endpoints access connections.
#service-control --stop envoy-sidecar ; service-control --start envoy-sidecar