vSAN optimal datastore policy configuration check shows warning after cluster upgrade to 9.1 or 9.1.1
search cancel

vSAN optimal datastore policy configuration check shows warning after cluster upgrade to 9.1 or 9.1.1

book

Article ID: 451544

calendar_today

Updated On:

Products

VMware vSAN VMware vSphere ESXi

Issue/Introduction

When vSAN Auto-policy management (introduced in vSAN 8.0U1) is enabled, upgrading a cluster to version 9.1 or 9.1.1 causes the 'vSAN optimal datastore policy configuration' health check to issue a false warning recommending vSAN ESA Auto-RAID, even though the applied policy is already optimal.

 

Environment

vSAN/vSphere 9.1.x

Cause

vSAN ESA Auto-RAID is a new feature introduced in vSAN 9.1. The warning arises from a minor interoperability issue between Auto-policy management and Auto-RAID within the vSAN control path.

Resolution

If the storage policy's current RAID level already aligns with the Auto-RAID target, no data movement will occur, even if the remediation UI dialog displays a warning indicating that significant data movement may be required. Refer the below table for Auto-RAID target FTT.

 

Type
Number of nodes
Auto-policy target FTT in 9.0 and lower release
Auto-policy target FTT in 9.1 and later release with Auto-RAID
Data movement required?
 With host rebuild reservation With host rebuild reservation
Standard single site clusters
< 3FTT=No data redundancyN/AFTT=No data redundancyNoNo
3FTT=1 failure - RAID-1 (Mirroring)N/AFTT=1 failure - RAID -5 (Erasure Coding)YesYes
4FTT=1 failure - RAID -5 (Erasure Coding)FTT=1 failure - RAID-1 (Mirroring)FTT=1 failure - RAID -5 (Erasure Coding)NoYes
5FTT=1 failure - RAID -5 (Erasure Coding)FTT=1 failure - RAID -5 (Erasure Coding)FTT=1 failure - RAID -5 (Erasure Coding)NoNo
6FTT=2 failures - RAID-6 (Erasure Coding)FTT=1 failure - RAID -5 (Erasure Coding)FTT=2 failures - RAID-6 (Erasure Coding)NoYes
7 and moreFTT=2 failures - RAID-6 (Erasure Coding)FTT=2 failures - RAID-6 (Erasure Coding)FTT=2 failures - RAID-6 (Erasure Coding)NoNo
Stretched clusters
< 3 per site/fault domainSite disaster tolerance =Site mirroring - stretched cluster
FTT=No data redundancy
N/ASite disaster tolerance =Site mirroring - stretched cluster
FTT=No data redundancy
NoNo
3 per site/fault domainSite disaster tolerance =Site mirroring - stretched cluster
FTT=1 failure - RAID-1 (Mirroring)
N/ASite disaster tolerance =Site mirroring - stretched cluster
FTT=1 failure - RAID -5 (Erasure Coding)
YesYes
4-5 per site/fault domainSite disaster tolerance =Site mirroring - stretched cluster
FTT=1 failure - RAID -5 (Erasure Coding)
N/ASite disaster tolerance =Site mirroring - stretched cluster
FTT=1 failure - RAID -5 (Erasure Coding)
NoNo
6 and more per site/fault domainSite disaster tolerance =Site mirroring - stretched cluster
FTT=2 failures - RAID-6 (Erasure Coding)
N/ASite disaster tolerance =Site mirroring - stretched cluster
FTT=2 failures - RAID-6 (Erasure Coding)
NoNo
2-node clustersANYSite disaster tolerance =Site mirroring - stretched cluster
FTT=No data redundancy
N/ASite disaster tolerance =Site mirroring - stretched cluster
FTT=No data redundancy
NoNo


1. If no data movement is required, proceed with updating the cluster DS (datastore) policy.
2. If data movement is required, update the cluster DS policy when the cluster has lower IO utilization, such as during a weekend, or off-peak hours.
3. If data movement is required but you wish to avoid it and maintain the current optimal FTT policy, disable Auto-policy management. Note that if the cluster configuration changes, you will need to manually modify the policy.

Additional Information

The issue will be fixed in the coming vSAN 9.1 patch release.