免責事項:これは英文の記事「'WARNING: NTPClock: 680: system clock apparently no longer synchronized to upstream time servers' on ESXi」の日本語訳です。記事はベストエフォートで翻訳を進めているため、ローカライズ化コンテンツは最新情報ではない可能性があります。最新情報は英語版の記事で参照してください。
WARNING: NTPClock: 680: system clock apparently no longer synchronized to upstream time servers
[root@esxi]: ntpq -p remote refid st t when poll reach delay offset jitter======================================================================== *<NTP-Server> .BD. 1 u 35 64 377 2.706 +1073.6 117.229
[root@esxi]: ntpq -c associationsind assid status conf reach auth condition last_event cnt===================================================================1 7023 96fa yes yes none sys.peer sys_peer 15
[root@esxi]: ntpq -c "rv 7023"associd=7023 status=96fa conf, reach, sel_sys.peer, 15 events, sys_peer,srcadr=##.##.##.##, srcport=123, dstadr=##.##.##.##, dstport=123,leap=00, stratum=1, precision=-13, rootdelay=0.000, rootdisp=10682.327,refid=BD, reftime=eb61175d.b0a783e8 <Day, Month date year Time>,rec=eb61175e.75b6c16b <Day, Month date year Time>, reach=377,unreach=0, hmode=3, pmode=4, hpoll=10, ppoll=10, headway=0, flash=00 ok,keyid=0, offset=+1073.6, delay=4.780, dispersion=15.386, jitter=117.229,xleave=0.080,filtdelay= 4.78 6.44 5.22 5.21 4.18 5.03 4.86 4.50,filtoffset= -3.24 -3.73 -3.48 -3.14 -3.03 -2.60 -2.36 -2.15,filtdisp= 18.12 15.83 31.94 47.60 63.75 79.14 94.76 110.58
vSphere ESXi 7.0.3
vSphere ESXi 8.x
デフォルトでは、同期が確立していない Windows サーバーは分散(dispersion)として 10 秒を選択し、同期状態が維持されている間、ポーリング間隔ごとにその分散を加算します。
一方、ESXi ホストはデフォルトで、ルート分散(root dispersion)が 1.5 秒を超える NTP 応答を受け入れません。
以下のいずれかの方法を用いて本事象を修正します。
ESXi の NTP 設定に tos maxdist 30 および iburst minpoll 3 maxpoll 4 のパラメータを追加します。
詳細な設定手順については、KB 313810を参照してください。