During NSX Federation 9.1 Local Manager (LM) to Global Manager (GM) import operations, the import workflow fails.
Symptom / Error Message: Global Manager: Error - Unable to import due to these unsupported features MultiTenancy. Viewing the details of the error: Entity VPC_CONNECTIVITY_PROFILE at site <site-name> is not supported for configuration import on GM. Please delete entity VPC_CONNECTIVITY_PROFILE from the site <site-name> and try again.
In the NSX Local Manager UI at the affected site, the Default VPC Connectivity Profile is present, but the option to delete it is greyed out.
VMware NSX 9.1 (NSX Federation)
VMware Cloud Foundation 9.1
An active IP Block association tied to the Default VPC Connectivity Profile triggers a MultiTenancy feature validation check during the LM-to-GM import process, causing the Global Manager to reject the site import.
Log into the NSX Local Manager UI at the target site.
Navigate to the Default VPC Connectivity Profile under VPCs > Profiles > VPC Connectivity Profile and edit its configuration.
Remove the associated IP Block mapping in the Private - Transit Gateway IP Blocks column and save the changes.
Retry the Local Manager import to the Global Manager.
After the LM import completes successfully, re-edit the Default VPC Connectivity Profile, re-assign the IP Block association, and save the profile.