CIS COMMON SERVICES FOR Z/OS 90S SERVICES DATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OS COMMON PRODUCT SERVICES COMPONENT Common Services Datacom/AD CA ecoMeter Server Component FOC EASYTRIEVE REPORT GENERATOR FOR COMMON SERVICES INFOCAI MAINTENANCE IPC UNICENTER JCLCHECK COMMON COMPONENT Mainframe VM Product Manager CHORUS SOFTWARE MANAGER CA On Demand Portal CA Service Desk Manager - Unified Self Service PAM CLIENT FOR LINUX ON MAINFRAME MAINFRAME CONNECTOR FOR LINUX ON MAINFRAME GRAPHICAL MANAGEMENT INTERFACE WEB ADMINISTRATOR FOR TOP SECRET Xpertware Compress Data Compression for MVS Compress Data Compression for Fujitsu

Issue/Introduction

Received notification of high-impact PTF RO92910 for CAIENF. Cannot put it on due to the following SMP/E messages: 

 

GIM41802I JCLIN PROCESSING WAS SUCCESSFUL FOR SYSMOD RO85315. 

GIM38201E ** THERE IS A MODID ERROR FOR MOD ENTRY CAS9P6LS IN SYSMOD RO85315. 

GIM31901I SYSMOD RO85315 DOES NOT SPECIFY TR87945 ON THE PRE OR SUP OPERAND. 

THAT IS CURRENTLY INSTALLED. 

GIM38201E ** THERE IS A MODID ERROR FOR MOD ENTRY CAS9P6US IN SYSMOD RO85315. 

GIM31901I SYSMOD RO85315 DOES NOT SPECIFY TR87945 ON THE PRE OR SUP OPERAND. 

THAT IS CURRENTLY INSTALLED.

GIM22601I APPLY PROCESSING FAILED FOR SYSMOD RO85315. 



TR87945 was previously installed to address a S0C4 in CCITCPGW. 

Should I be adding PRE or SUP information to RO85315, or should I start messing with SMPE RESTOREs?

Cause

The cause of the SMP/E messages is that TR87945 was not specified on the PRE or SUP statement delivered along with RO85315. It turns out that the changes in TR87945 were sourced into RO90383 where RO85315 is a PREREQ.    

Environment

CA Common Services r14.1

Resolution

Download and RECEIVE PTF RO90383.

APPLY RO90383 and RO92910 together with a GROUPEXTEND