Unable to view flows for a time range more than 31 days.
search cancel

Unable to view flows for a time range more than 31 days.

book

Article ID: 450710

calendar_today

Updated On:

Products

VCF Operations for Networks

Issue/Introduction

  • Following error received when trying to retrieve flows more than 31 days:

Environment

VCF Operations for Networks

Cause

  • The product is designed to store network flow data for a maximum of 31 days (1 month).
  • This is a hardcoded limit intended to ensure system performance and manage disk space on the platform cluster.
  • Data older than 31 days is automatically purged.
  • Refer following Broadcom document for more details: Configure Data Retention Interval

Resolution

To work around this issue, you can set up a Streaming Databus to retain flow data for longer than 31 days.

Prerequisites for extended flow retention (>31 days):

  • The flow data will be stored on a remote server.
  • You need an HTTP server configured to accept requests from the Databus. Once this endpoint is active, VCF Operations for Networks will automatically push the flow data to it.
  • The remote server must be able to understand the format the Databus is sending.
  • To configure Databus on VCF Operations for Networks, refer: Working with the Streaming Databus

Additional Information

Understanding the Databus Terminologies and Capabilities