VCF Installer Failing to Deploy new VVF Instance, "Internal errors: Status polling timed out".
search cancel

VCF Installer Failing to Deploy new VVF Instance, "Internal errors: Status polling timed out".

book

Article ID: 450645

calendar_today

Updated On:

Products

VMware SDDC Manager / VCF Installer

Issue/Introduction

Deployment Fails:

The Fleet lifecycle 'OVA component installation' task with ID ###### failed. Internal errors: Status polling timed out. Review the logs to check operation progress. Increase the timeout value if the operation requires more time., Status polling timed out. Review the logs to check operation progress. Increase the timeout value if the operation requires more time., Status polling timed out. Review the logs to check operation progress. Increase the timeout value if the operation requires more time., Status polling timed out. Review the logs to check operation progress. Increase the timeout value if the operation requires more time., Status polling timed out. Review the logs to check operation progress. Increase the timeout value if the operation requires more time., Status polling timed out. Review the logs to check operation progress. Increase the timeout value if the operation requires more time., Status polling timed out. Review the logs to check operation progress. Increase the timeout value if the operation requires more time. Reference Token: #####

Environment

SDDC Manager 9.1

Cause

Time zone mismatch causing time skew. 

Resolution

Configure functional reachable NTP servers and address time skew issues.

Additional Information

For additional information on VCF Installer requirements, please see: Deploy VCF Installer