VMware vSAN
A drive firmware issue occurs when the drive's Power-On Hours (POH) counter exceeds 65,535 hours (approximately 7.5 years of uptime).
localcli storage core device smart get -d naa.################
SMART Data for Disk : naa.################Parameter Value Threshold Worst Raw-----------------------------------------------------------Health Status OK N/A N/A N/ARead Error Count 100 50 100 0Power-on Hours 100 0 100 65587 <===
This issue is believed to also impact environments using servers from other vendors using Micron 5x00 series drives. The fix requires applying a manufacturer-provided firmware update.
Dell:
PowerEdge: Micron 5x00 Series solid state drive Performance Degradation after 65,535 POH | Dell UK