VMs running on vSAN become hung and unresponsive with drives reporting high DAVG latency.
search cancel

VMs running on vSAN become hung and unresponsive with drives reporting high DAVG latency.

book

Article ID: 450395

calendar_today

Updated On:

Products

VMware vSAN VMware vSAN 8.x

Issue/Introduction

  • Virtual Machines residing on a vSAN datastore become hung, unresponsive, or experience severe read/write latency.

  • vSphere performance charts and esxtop show sustained, massive spikes in Device Average Latency (DAVG) on specific host disk(s).

  • Overall disk throughput drops to less than 1 MB/s, despite vSAN health checks and SMART data reporting the physical drives as "Healthy."

  • This affects environments using Micron 5x00 series solid-state drives (or OEM variants from vendors like HPE, Cisco, or Lenovo) as vSAN Cache-tier and/or Capacity-tier devices

  • vSAN Disk-Groups may report high levels of SSD congestion.
  • vSAN Cache-tier and/or Capacity-tier devices may be marked as failed/offline by vSAN DDH (Dying Disk Handling) due to sustained excessively high latency (Dying Disk Handling (DDH) in vSAN).

Environment

VMware vSAN

Cause

A drive firmware issue occurs when the drive's Power-On Hours (POH) counter exceeds 65,535 hours (approximately 7.5 years of uptime).

localcli storage core device smart get -d naa.################

SMART Data for Disk : naa.################
Parameter                       Value  Threshold Worst  Raw
-----------------------------------------------------------
Health Status                      OK     N/A        N/A    N/A
Read Error Count                   100    50         100    0
Power-on Hours                     100    0          100    65587 <===

Resolution

This issue is believed to also impact environments using servers from other vendors using Micron 5x00 series drives. The fix requires applying a manufacturer-provided firmware update.

HPE:
Online HDD/SSD Flash Component for Linux (x64) - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives | HPE Support

Dell:
PowerEdge: Micron 5x00 Series solid state drive Performance Degradation after 65,535 POH | Dell UK

Lenovo:
Micron 5100, 5200 and 5300 SSD command timeout results in task abort error and drive offline condition - Lenovo ThinkSystem - Lenovo Support EG