When attempting to install VMware ESXi 8.0u3 (specifically using a Cisco custom ISO) on Cisco UCS B200-M5 blades where boot volumes are hosted on an Infinidat Infinibox SAN, the installation process may fail.
Symptoms:
The issue is triggered when the Fibre Channel (FC) uplink speed is set to 8 Gbps on the Cisco MDS switch and the fill pattern is not configured correctly. This can cause the uplinks to lose synchronization intermittently or experience bad packets, leading to the failure of storage-intensive tasks like VMFS partitioning. This behavior is documented under Cisco BugID: CSCvj31676.
To resolve this issue, set the fill pattern to IDLE on the Cisco MDS switch ports connected to the Fabric Interconnects.