Stateless ESXi hosts deployed via Auto Deploy detect physical onboard interfaces (e.g., LOM Port 1 and LOM Port 2) that are not configured in the host profile or intended for use. This occurs even when the host profile is removed or the host is rebooted.
ESXi enumerates all hardware devices presented by the system BIOS/CIMC during the boot sequence. On certain Cisco server models, the Dual Embedded Intel X550 10GBASE-T LOM ports are enabled by default in the BIOS. During a stateless Auto Deploy boot, ESXi identifies these PCI devices and assigns them vmnic aliases (e.g., vmnic0, vmnic1) before applying the Host Profile, which may conflict with the intended numbering of virtual interfaces (vNICs) defined in the Cisco Service Profile.
To resolve this behavior, the hardware visibility of the onboard ports must be modified at the BIOS/CIMC level. Contact the server vendor support to modify this setting.
How VMware ESXi determines the order in which network device names are assigned to the devices
To speak with a customer representative or a Support Engineer, see Contact Support.