CAL2X030E CA-7 ICMDSECT NOT PRESENT ON SYSTEM error using CA7TOUNI utility
search cancel

CAL2X030E CA-7 ICMDSECT NOT PRESENT ON SYSTEM error using CA7TOUNI utility

book

Article ID: 449625

calendar_today

Updated On:

Products

CA 7 Workload Automation

Issue/Introduction

When running the CA7TOUNI utility to perform a Cross Platform Submit process, the job fails with the error: CAL2X030E CA-7 ICMDSECT NOT PRESENT ON SYSTEM.

This error occurs even when the non-default CA 7 instance is active and successfully initialized by CAIRIM (CAS9). The utility fails because it cannot locate the Instance Control Block (ICMDSECT) in common storage for the requested instance.

Environment

Release: 12.0, 12.1

Component: WA CA 7 Edition

Cause

The CA7TOUNI utility defaults to instance CA71. It cannot find the ICMDSECT for environments using non-default instances (e.g., CA74). 

Resolution

Running the CA7TOUNI program requires ICMDSECT to be loaded on the default CA71 instance.

To resolve the issue, add the default instance CA71 to the environment if non-default instances have already been added.

Additional Information

Refer to the tech docs link for additional details on error message CAL2X030E:

CAL2X030E