SRM sites are not visible in VMware Aria Automation Orchestrator inventory — VMware Live Site Recovery plug-in troubleshooting matrix
search cancel

SRM sites are not visible in VMware Aria Automation Orchestrator inventory — VMware Live Site Recovery plug-in troubleshooting matrix

book

Article ID: 449253

calendar_today

Updated On:

Products

VCF Automation VMware Live Recovery

Issue/Introduction

After integrating VMware Live Site Recovery (SRM) with VMware Aria Automation via the Automation Orchestrator plug-in, SRM sites are missing from the Orchestrator inventory or selection views. Symptoms include:

  • The Add SRM Site workflow completes successfully, but the site never appears in the inventory.
  • SRM sites that were visible disappear after upgrading VMware Live Site Recovery.
  • SRM sites disappear after replacing the SRM certificate.

Environment

  • VMware Aria Automation / Automation Orchestrator: 8.18.x
  • VMware Live Site Recovery (LSR): 9.0.x
  • Orchestrator Plug-in for VMware Live Site Recovery: 9.0.x

Cause

The Orchestrator plug-in must be version-compatible with the LSR server; one specific plug-in build carries a known defect; and SRM certificate replacement invalidates already-registered sites (a documented caveat in the plug-in 9.0 release notes).

Resolution

What happenedLSRPlug-inRoot causeActionDetails
Upgraded LSR to 9.0.5; existing sites vanished9.0.59.0.1 or olderVersion incompatibility between upgraded server and legacy plug-inUpgrade the plug-in to 9.0.4: delete the current plug-in, install the new oneKB 429720
Fresh integration; Add SRM Site succeeds but the site never appears9.0.29.0.2 build 24837754Known defect in that plug-in buildInstall hot-patch build 25292365 (attached to the KB), per the plug-in install documentationKB 440343
Replaced the SRM certificate; site vanished9.0.xanyCertificate change invalidates the registered siteIn Orchestrator ClientLibrarySRMConfiguration, run: Remove Local SitesConfigure Local Sites (accept the new certificate) → Login Remote SitesKB 393838

In all cases, verify plug-in ↔ server compatibility in the interoperability matrix before upgrading either side, and schedule the matching plug-in upgrade in the same change window as any LSR upgrade.