xvdxghd3fyhdehijgihk1ievzfekj3xc@####).pktcap-uw) show inbound traffic arriving on multiple physical uplinks (e.g., vmnic4 and vmnic8) in the LAG simultaneously.A traffic processing anomaly occurs in the NSX Edge data plane during bridging operations on Large sized Edge nodes. The bridge may forward duplicated frames across all active uplinks in the LAG instead of steering traffic to a single member.
To resolve this behavior, the Edge nodes must be appropriately sized to handle the data plane overhead required for bridging, and the environment should be updated to the latest maintenance release.
Migrate the affected Edge segment or bridge to an Extra Large (XL) Edge node. Testing has confirmed that the XL form factor handles the bridging logic more reliably.
If the above workaround does not resolve the issue, open a support case with Broadcom. Contact Broadcom support