"Operations for Networks-NSX-T Edge Node Pnic Status is 'Down'".NETOPA00006 errors in the netopa logs."CPUID Admission failure in path: host/vim/vmvisor/nsx-datapath-ctrs".The alert is a false positive triggered by CPU resource contention at the ESXi host level. The netopa agent (responsible for exporting network telemetry to Aria) requires resources from the nsx-datapath-ctrs resource pool.
When the hypervisor host is overcommitted or experiencing high CPU contention, the scheduler may deny CPU admission to this pool. This causes the telemetry agent to time out (NETOPA00006) when reporting to Aria. Aria interprets the missing heartbeat/telemetry as a physical adapter failure.
Hardware or physical network remediation is typically not required. Instead, address the host-level resource starvation:
esxtop'. Monitor the Edge VM and system resource groups for high CPU Ready (%RDY) or Co-Stop (%CSTP)./etc/init.d/hostd restart/etc/init.d/vpxa restartWhile the physical network is not impacted, these false positives can mask real hardware failures if left unaddressed. Prolonged CPU admission failure for NSX system processes may also affect other management plane functions
To create or open a technical or non-technical support case, log in to the Broadcom Support Portal. Once logged in, select My Cases from the left menu and then click Create Case in the upper-right corner. For a detailed walkthrough of the process, including how to manage existing cases, refer to the knowledge article Creating and Managing Broadcom