Following a Fabric switch rebalancing or maintenance task, multiple ESXi hosts within a cluster report offline Fibre Channel adapters (vmhbas). This results in production VM disruption, where VMs become inaccessible or stuck on boot due to storage path loss.
From /var/run/log/vobd.log:
2026-07-15T03:31:11.910Z In(14) vobd[20##]:[APDCorrelator]:[vob.storage.apd.timeout]Device or filesystem with identifier [naa.600507##############] has entered the All Paths Down Timeout state after being in the All Paths Down state for 140 seconds. I/Os will now be fast failed.
VMware vSphere ESXi 8.x
Fabric rebalancing tasks can cause a temporary loss of path redundancy. If a device only has paths through the affected fabric segment, an APD state is triggered. ESXi enters APD when all paths to a storage device become unavailable; if residual references remain in the management stack after physical connectivity is restored, the host may fail to reclaim the paths automatically.
From vCenter UI> Host > Configure > Storage Adapters
To restore service and clear the APD state, follow these steps:
Review fabric redundancy configurations to ensure hosts have paths distributed across multiple independent fabric segments.