The service mesh deployment fails due to the failure of the deployment of IX appliance,
As the primary engine for VMware HCX, the HCX-IX Interconnect Appliance manages data replication and virtual machine mobility. The Service Mesh deploys it automatically to serve as the direct data plane handler connecting your source and destination environments
HCX 4.x
The Tasks view within HCX UI shows following error message
Failed to fetch the edge details for appliance: xxxxx-xxxx-xxxx-xxxxxxx Error"Failed to fetch edgeinfo applianceid xxxxx-xxxx-xxxx-xxxxxxx. Failed to get edge info response for appliance xxxxx-xxxx-xxxx-xxxxxxx
The issue may happen due to the Configuration mismatch where the Network Profile references a non-existent dvportgroup and that dvportgroup was assigned to IX appliance, causing communication issue between the HCX Manager and the NEW-IX appliance on the management network.