When you attempt to upload a Broadcom ISV SCRT report (CSV or TXT) to the Broadcom SCRT Repository, the upload may fail with one of the following messages:
Review the SCRT report looking for the following lines in the E5 section for each system being reported. Note that the following two entries may not appear in the same order.
Allocate DASD Space and Placement with Quota Manager 12.05.00 ----12.05.00 ----
The SCRT application rejects the report because it contains unexpected values generated for a specific product. This data mismatch is often associated with "Allocate DASD Space and Placement with Quota Manager" and is surfaced by changes introduced in Broadcom Product Catalog Version 16.
To resolve this error and successfully upload your report, you must regenerate the report using an older version of the Broadcom Product Catalog.
The potential for this problem may exist for other reasons or other products, but for now this has only been witnessed in situations involving Allocate DASD Space and Placement 12.05.00
If you experience the problem but are not running Allocate DASD Space and Placement 12.05.00, please open a support case with the Common Components and Services for z/OS support team.