When attempting to install a Secondary Failover Management Server for UVMS 7.01.14 (or other 7.01.xx versions) on Windows, the installation fails during the UVMS configuration phase.
The installer returns the following error:SEVERE_ERROR MESSAGE= "unable to configure the UVMS"
The UVMS_ISS_installation.log or console may display misleading errors such as:
"The system cannot find the batch label specified - erreur_usage""Java error: unable to find JVM location"A product defect in the uniinstall_failover.cmd script used by the 7.01.xx installers prevents the correct configuration of the secondary node when connecting to the primary UVMS server.
This issue is scheduled to be fixed in UVMS version 7.01.31.
Workaround
To complete the installation using the current 7.01.xx installer, you must manually replace the uniinstall_failover.cmd script during the installation process:
%TEMP% folder.UVMS_ISS_installation.log for a line containing a path similar to:...\{GUID}\{1A3EA53C-9466-4547-9BDE-525B8F637A99}\{1A3EA53C-9466-4547-9BDE-525B8F637A99}).uniinstall_failover.cmd.