iDRAC vSwitch Recreated on Reboot Due to OEM Jumpstart Scrip
search cancel

iDRAC vSwitch Recreated on Reboot Due to OEM Jumpstart Scrip

book

Article ID: 446189

calendar_today

Updated On:

Products

VMware vSphere ESXi VMware vSphere ESXi 8.0

Issue/Introduction

  • An ESXi host continually recreates a converged switch (cswitch) named iDRAC bound to the vusb0 pseudo-NIC after a reboot.

  • This occurs despite explicitly disabling the native BMC network feature, ensuring no stale configurations exist in esx.conf, and verifying that the Dell iDRAC Service Module VIB (dcism) is not installed.

  • The following log signatures are observed in /var/run/log/vmkernel.log

    NetPortset: 2236: Activating portset #3 as iDRAC (cswitch) with 9216 ports, index mask is 0x3fff
    NetPort: 1621: enabled port 0x600000b with mac <##-##-##-##-##-##>
    cswitch: VSwitchActivate:10099: [nsx@6876 comp="nsx-esx" subcomp="vswitch"]Activating switch iDRAC by setting runtime option override.

Environment

VMware vSphere ESXi

Cause

  • An OEM Jumpstart script bundled within the Dell-customized ESXi ISO is reacting to the hardware-level presentation of the virtual USB device (vusb0).

  • The script forcefully injects the network configuration during the host boot sequence because the "OS to iDRAC Pass-Through" feature is enabled on the physical Baseboard Management Controller.

Resolution

To resolve the issue, please contact Dell Hardware Support for alignment before proceeding with the maintenance.

  • Log in to the out-of-band iDRAC web interface of the affected physical server and disable the iDRAC Service Module Setup.

  • Perform a graceful reboot of the ESXi host to commit this hardware-level configuration change.

  • This action removes the vusb0 pseudo-NIC presentation to the hypervisor, successfully preventing the execution of the Jumpstart script.

Additional Information

Reconfigure Dell iDRAC USB NIC address