CEM0612E CEM Switch Policy Failure
search cancel

CEM0612E CEM Switch Policy Failure

book

Article ID: 445460

calendar_today

Updated On:

Products

Compliance Event Manager

Issue/Introduction

Receive a policy refresh failure (e.g., CEM0612E CEM Change Monitor PDS Name Table Build Failure) when trying to activate a policy set that includes a PDS Monitor statement. The policy works for other listeners like Alert or Warehouse, but fails for the Monitor listener.

Environment

Z/OS

CEM

Cause

The failure occurs because no data sets are correctly specified within the PDS monitor policy statement. This typically happens if you enter a data set name in the user interface but do not explicitly add it to the statement using the required controls.

 

Resolution

To resolve this issue, ensure that the data set name is properly registered within the policy statement