SARSTC Abend S1FB Due to Report Collection Problem
search cancel

SARSTC Abend S1FB Due to Report Collection Problem

book

Article ID: 44467

calendar_today

Updated On:

Products

Deliver View

Issue/Introduction

Introduction:

When a S1FB abend occurs in a CA View started task, there will be a message similar to:

   CCSR010E SARSDAPI S1FB at 00E3A5EC LMOD IATDMEB3

The above message indicates that View needs to shut itself down because of its having a problem collecting a report.

 

Instructions:

. The problem reports will appear in View with a location of OPEN.

. In the View Sysout Selection List, to the left of the report, issue "C" (for Clean). 

. Go to the JES queue, and place the report(s) causing the problem either on hold or purge them.

. Bring up SARSTC with "/S sarstc,OPT=STOPBU". 

. Have a View backup run. 

. A minimum of 4 hours later, after the first issue of "C" on the OPEN reports, issue the "C" again.

 

The reports should go from a location of OPEN to DISK.

 

Environment

Release: OUTDTI00200-12.2-Deliver-Output Management-Interface for Native TSO
Component: