Error: DC Locator is not running false positive alerts in ad_server probe
search cancel

Error: DC Locator is not running false positive alerts in ad_server probe

book

Article ID: 443965

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

The ad_server probe (v2.10-T1) generates critical alerts stating "DC Locator is not running" with a status of 1. However, native Windows diagnostic tools confirm the service is healthy.

Specific symptoms include:

  • The probe reports status = 1 (Failure).
  • Thresholds for status > 0 are breached, triggering constant alerts.
  • Commands like nltest /dsgetdc:[DOMAIN] /pdc and netdom query fsmo run successfully on the same server.

Environment

  • DX UIM 23.4.*
  • ad_server probe v2.10-T1

Cause

This issue is caused by a product defect (DE677840). 

Resolution

Fixed in ad_server release 2.10-T2 and higher.

  1. Download the attached ad_server-2.10-T2-20260611.003216-1-T2.zip build
  2. Import to IM or AC and deploy to the ad_server probe. 

Additional Information

These fixes will be included in the next GA probe and contain any previous delivered fixes. 

Attachments

ad_server-2.10-T2-20260611.003216-1.zip get_app