2026-01-01T00:00:00.000Z In(182) vmkernel: cpu53:2098219)NMP: nmp_ThrottleLogForDevice:3893: Cmd 0x88 (0x45b9c27ca480, 2101026) to dev "naa.####" on path "vmhba#:C#:T#:L#" Failed:
2026-01-01T00:00:00.000Z In(182) vmkernel: cpu53:2098219)NMP: nmp_ThrottleLogForDevice:3898: H:0x7 D:0x0 P:0x0 . Act:EVAL. cmdId.initiator=0x430e25e85580 CmdSN 0x800e004e
2026-01-01T00:00:00.000Z Wa(180) vmkwarning: cpu53:2098219)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:235: NMP device "naa.####" state in doubt; requested fast path state update...
2026-01-01T00:00:00.000Z In(182) vmkernel: cpu53:2098219)ScsiDeviceIO: 4697: Cmd(0x45b9c27ca480) 0x88, CmdSN 0x800e004e from world 2101026 to dev "naa.####" failed H:0x7 D:0x0 P:0x0
vCenter Server
Storage issues are affecting Virtual Machine Performance.
Contact the Storage Vendor for assistance in troubleshooting the Storage issues.
When performing Virtual Machine performance troubleshooting with ESXi storage, use command line tools to identify a specific disk or LUN connected to ESXi.
Troubleshooting ESX/ESXi virtual machine performance issues
If you identify a storage-related issue: