Receiving the following messages when starting up a new CICS region:
DV: START-UP - DVX0045E CANNOT FIND AN OPENED URT
DV: START-UP - DVX0018I TRANSACTION COMPLETED
DB: START-UP - DC00220E NO URTS AVAILABLE.
DB: START-UP - DC00270W CICS INTERFACE UNUSABLE
DB: START-UP - DC00380I TRANSACTION COMPLETED
Component: DBC
You may be missing URT modules in your CUSLIB (DBURT002, 003, 010...etc.)
-or-
You may have default DBCVTPR PREFIX set to DBURT and are using DBFLT for your URT modules.
Double check your macro DBCVTPR in your CUSMAC library.
-or-
Verify the CSD definitions exist. In a previous case, the CSD had been removed and URT was correct.
Additional Information from Quickref:
DVX0045E CANNOT FIND AN OPENED URT
Reason: Attempt to connect to DATACOM/DB Multi-User
Facility failed because no open User Requirements
Tables were found.
Action: Open at least one User Requirements Table and retry
the function.
DC00220E NO URTS AVAILABLE
Reason: The URTs cannot be loaded. The system generation macro, DBCVTPR, may contain an operand for the PREFIX= parameter different from any URT prefix in the CICS load library or the URTs may be missing from the CICS load library.
Action: Issue DBOC INQ=GENOPTS (see the User Guide) to verify the currently specified prefix name. Verify that the URTs have been added to the CICS load library.