I am getting the following error when installing a new CA Datacom/AD 14.0 for ENF:
DB10053 - MUF RUNNING, FUNCTION REQUIRES MUF DOWN,
This is happening when executing AXNEW01.
TARGET_MUF_LIST and CXXNAME must be unique inside the Sysplex.
In this case customer had already specified TARGET_MUF_LIST=() for an existing Jobtrac environment.
So, changing TARGET_MUF_LIST to a meaningful CXXNAME name resolved the problem.
In CA Datacom/AD 14.0 release the following output may be helpful to diagnostic the problem:
//DBUTLTY EXEC PGM=DBUTLTY,REGION=6M,PARM='/PGMMONTH=1
//STEPLIB DD DSN=CAI.DATACOM.R14.CUSLIB,DISP=SHR
// DD DSN=CAI.DATACOM.R14.CAAXLOAD,DISP=SHR
//SYSPRINT DD SYSOUT=*
//SYSOUT DD SYSOUT=*
//SYSPUNCH DD DUMMY
//DDSNAP DD SYSOUT=*
//SNAPER DD SYSOUT=*
//SYSUDUMP DD SYSOUT=*
//*
//SYSIN DD *
SET OPTION1=ON-ERROR-CONTINUE
SET OPTION1=DUMPPGM=DBSIDPR
REPORT MEMORY=MVS
/*
Which should list your DBSIDPR parameters.