Example for the JSON API input for stretching a vSAN cluster in VMware Cloud Foundation 9.1 across two Availability Zones (AZ1 and AZ2) utilizing the SDDC Manager API. This article outlines JSON specification needed when using Link Aggregation Control Protocol (LACP).
VMware Cloud Foundation (VCF) 9.1
This Example is used if the vDS uplinks are configured using Link Aggregation Control Protocol (LACP). Active
uplinks are explicitly referenced as LAG-0 / LAG-1 .
(Note: This example does not cover formatting and is for guidance only)
"clusterStretchSpec": {
"deployWithoutLicenseKeys": true,
"hostSpecs": [
{
"id": "<ESX-HOST-UUID-1>",
"hostname": "<FQDN-HOST-1>",
"hostNetworkSpec": {
"networkProfileName": "<NSX-Sub-Cluster-Profile-AZ2>",
"vmNics": [
{ "id": "vmnic0", "vdsName": "<vDS-Name-AZ1>", "uplink": "LAG-0" },
{ "id": "vmnic1", "vdsName": "<vDS-Name-AZ1>", "uplink": "LAG-1" }
"id": "<ESX-HOST-UUID-2>",
"hostname": "<FQDN-HOST-2>",
"hostNetworkSpec": {
"networkProfileName": "<NSX-Sub-Cluster-Profile-AZ2>",
"vmNics": [
{ "id": "vmnic0", "vdsName": "<vDS-Name-AZ1>", "uplink": "LAG-0" },
{ "id": "vmnic1", "vdsName": "<vDS-Name-AZ1>", "uplink": "LAG-1" }
"id": "<ESX-HOST-UUID-3>",
"hostname": "<FQDN-HOST-3>",
"hostNetworkSpec": {
"networkProfileName": "<NSX-Sub-Cluster-Profile-AZ2>",
"vmNics": [
{ "id": "vmnic0", "vdsName": "<vDS-Name-AZ1>", "uplink": "LAG-0" },
{ "id": "vmnic1", "vdsName": "<vDS-Name-AZ1>", "uplink": "LAG-1" }
"id": "<ESX-HOST-UUID-4>",
"hostname": "<FQDN-HOST-4>",
"hostNetworkSpec": {
"networkProfileName": "<NSX-Sub-Cluster-Profile-AZ2>",
"vmNics": [
{ "id": "vmnic0", "vdsName": "<vDS-Name-AZ1>", "uplink": "LAG-0" },
{ "id": "vmnic1", "vdsName": "<vDS-Name-AZ1>", "uplink": "LAG-1" }
"networkSpec": {
"networkProfiles": [
{
"isDefault": false,
"name": "<NSX-Sub-Cluster-Profile-AZ2>",
"nsxtHostSwitchConfigs": [
{
"ipAddressPoolName": "<TEP-Pool-Name-AZ2>",
"uplinkProfileName": "<Uplink-Profile-Name-AZ2>",
"vdsName": "<vDS-Name-AZ1>",
"vdsUplinkToNsxUplink": [
{ "nsxUplinkName": "LAG", "vdsUplinkName": "LAG" }
"nsxClusterSpec": {
"ipAddressPoolsSpec": [
{
"name": "<TEP-Pool-Name-AZ2>",
"subnets": [
{
"cidr": "<TEP-CIDR-AZ2>",
"gateway": "<TEP-Gateway-AZ2>",
"ipAddressPoolRanges": [
{ "start": "<TEP-IP-Start>", "end": "<TEP-IP-End>" }
,
"uplinkProfiles": [
{
"name": "<Uplink-Profile-Name-AZ2>",
"transportVlan": "<Transport-VLAN-ID>",
"teamings": [
{
"name": "DEFAULT",
"policy": "FAILOVER_ORDER",
"standByUplinks": [],
"activeUplinks": ["LAG"]
"isEdgeClusterConfiguredForMultiAZ": false,
"witnessSpec": {
"fqdn": "<Witness-Host-FQDN>",
"vsanCidr": "<vSAN-CIDR-Witness>",
"vsanIp": "<vSAN-IP-Witness>"
},
"witnessTrafficSharedWithVsanTraffic": false