'High pNic error rate detected' on Intel X710 adapters
search cancel

'High pNic error rate detected' on Intel X710 adapters

book

Article ID: 440989

calendar_today

Updated On:

Products

VMware vSAN VMware vSphere ESXi

Issue/Introduction

Symptoms

  • The vSAN Health Service triggers the alarm High pNic error rate detected on an ESXi host.
  • Intel X710 (Intel(R) Ethernet Controller X710 for 10GbE SFP+) network adapters reporting Transmit errors with ring buffer exhaustion.
  • No immediate vSAN performance degradation is reported, but the alarm persists or triggers intermittently.
  • Physical network adapter statistics show non-zero counters for transmit queue constraints.

Environment

VMware vSAN 8.x

Intel(R) Ethernet Controller X710 for 10GbE SFP+

Cause

The issue is caused by transmit (TX) ring buffer exhaustion on the physical network adapter (Intel X710). This occurs when bursty vSAN traffic exceeds the driver's currently allocated buffer capacity.

When the TX ring buffer is saturated, the driver cannot accept new packets from the VMkernel, causing the txBusy and queueFull counters to increment. The restartQueue value indicates the driver had to reset the transmission logic to recover from this state.

vmnic3 stats :

txq0: totalPkts=50889064629 totalBytes=181267271786288 restartQueue=11 txBusy=10 queueFull=10 pktDropped=0

Resolution

Step 1: Verify Statistics

Run the following command on the affected ESXi host to identify the error type for the specific vmnic (e.g vmnic3)

# esxcli network nic stats get -n vmnic3

Review the output for the following indicators:

  • restartQueue > 0
  • txBusy > 0
  • queueFull > 0

Step 2: Check Ring Buffer Presets

# esxcli network nic ring current get -n vmnic3

# esxcli network nic ring preset get -n vmnic3

Example findings on Intel X710

  • Current RX:1024, TX:1024
  • Max Supported: Max RX:4096, Max TX: 4096

Step 3: Increase Ring Buffer Size

If the error counters continue to increment during peak workloads, expand the ring buffer sizes to the maximum supported by the hardware driver to better absorb traffic bursts:

Review this command before running it.

# esxcli network nic ring current set -n vmnic3 -r 4096 -t 4096

Note: Increasing ring buffers uses more system memory. Ensure the host has adequate resources before applying.

Step 4: Validate Physical Layer

If the alarm persists after buffer adjustment, engage the hardware vendor and physical networking team to inspect:

  • SFP transceivers and fiber cables.
  • Switch port configurations for potential Layer 1 backpressure.
  • Flow control settings on the physical switch.