Windows VM Boot Failure due to ESXi Local Datastore Latency
search cancel

Windows VM Boot Failure due to ESXi Local Datastore Latency

book

Article ID: 440825

calendar_today

Updated On:

Products

VMware vSphere ESXi

Issue/Introduction

  • Windows Virtual Machines (VMs) fail to boot with errors such as "Disk Read Error" or "Inaccessible Boot Device."
  • The ESXi host reports high latency or connectivity issues on local datastores (e.g., RAID-6 configurations).
  • VMs may boot successfully if migrated to a different datastore or host.
    • Operations such as browsing the datastore or opening a remote console are slow or unresponsive.

Environment

VMware ESXi 8.x

VMware ESXi 9.x

Local Datastore with RAID_5 and RAID_6 configured.

Cause

When one or more hard disks used in the backend RAID to create local datastore are experiencing hardware issues (failure or latency), would show up the latency on ESXi for the respective LUN/Disk. 

In local RAID scenarios, a failing or rebuilding physical drive can cause I/O response times to spike into the thousands of milliseconds, exceeding the Guest OS timeout threshold during the boot process.

Resolution

1. Validate Storage Performance

  • ESXTOP Analysis: Run esxtop and press d to view disk metrics. Monitor the DAVG/cmd column. Values consistently above 10ms for spindle disks or 1-2ms for flash indicate a performance bottleneck.
  • Log Review: Check /var/run/log/vmkernel.log for the following indicators:
    • ScsiDeviceIO: 1513: Device naa.### performance has deteriorated
    • NMP: nmp_ThrottleLogForDevice: ... Failed: H:0x7 D:0x0 P:0x0 (Storage Initiator Error)
    • WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:235: NMP device "naa.###" state in doubt

2. Physical Hardware Inspection

  • Verify RAID Status: Use the hardware vendor's management tools (e.g., DELL iDRAC, HP iLO) to check for failed or rebuilding disks in the RAID set.
  • Hardware Replacement: If a drive has failed, replace it and allow the RAID rebuild to complete before attempting to boot high-I/O VMs.
  • Firmware/Drivers: Ensure the Storage Controller (HBA) firmware and drivers are aligned with the .

3. Environmental Checks

  • If the issue persists despite healthy hardware, engage the hardware vendor to perform a deep-dive analysis of the storage controller and Fibre Channel fabric (if applicable) to check for CRC errors or port flaps.