VMware ESXi 8.x
VMware ESXi 9.x
Local Datastore with RAID_5 and RAID_6 configured.
When one or more hard disks used in the backend RAID to create local datastore are experiencing hardware issues (failure or latency), would show up the latency on ESXi for the respective LUN/Disk.
In local RAID scenarios, a failing or rebuilding physical drive can cause I/O response times to spike into the thousands of milliseconds, exceeding the Guest OS timeout threshold during the boot process.
esxtop and press d to view disk metrics. Monitor the DAVG/cmd column. Values consistently above 10ms for spindle disks or 1-2ms for flash indicate a performance bottleneck./var/run/log/vmkernel.log for the following indicators:ScsiDeviceIO: 1513: Device naa.### performance has deterioratedNMP: nmp_ThrottleLogForDevice: ... Failed: H:0x7 D:0x0 P:0x0 (Storage Initiator Error)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:235: NMP device "naa.###" state in doubt