No message for CICS max task threshold
search cancel

No message for CICS max task threshold

book

Article ID: 4401

calendar_today

Updated On:

Products

SYSVIEW Performance Management NXBRIDGE - SYSVIEW/ENDEVOR

Issue/Introduction

Issue:    

It appears that when CICS reaches max task, no alerts or messages are coming out of Sysview. I would like to get a message if possible.

Environment

Release: FAQSO.00200-14.1-SYSVIEW-Performance Management
Component:

Resolution

Resolution:    

The state metric MXTTASK is evaluated on a time interval basis. If CICS is in a MXTTASK state at the time checked, the exception will be raised. 

Short occurances of CICS max task can go unnoticed by SYSVIEW with regard to reporting it as a "current" condition or state. 

The system data collection record (CSYSDATA), will report the number of times max task was reached during an interval. You can also see the MAXTASK by performing the CTASKS command. 

As the MXTTASK variable is a SYSTEM-CONDITION schedule, you can see how often (ie: the interval), this schedule will wake up by performing the 

CSCHED command from Sysview and checking the EVERY column for how often this is set to check.