Configuring Memory Tiering over NVMe Using Hardware RAID Controllers in ESXi 9.0
search cancel

Configuring Memory Tiering over NVMe Using Hardware RAID Controllers in ESXi 9.0

book

Article ID: 439781

calendar_today

Updated On:

Products

VMware vSphere ESXi

Issue/Introduction

When configuring Memory Tiering over NVMe in ESXi 9.0,
administrators may encounter performance warnings when using logical volumes presented by hardware RAID controllers.

Even when using NVMe physical disks, the ESXi storage stack may flag the logical device with the following message:
"Using a non NVMe storage device, performance maybe degraded."

This article outlines the configuration steps and clarifies support for NVMe devices behind a RAID controller.

Environment

VMware ESXi 9.0

Cause

Memory Tiering natively supports NVMe devices behind RAID controllers.
The performance warning occurs because the logical device presented by the RAID controller is not identified as a raw NVMe namespace by the ESXi storage stack,
despite being backed by high-performance NVMe physical disks.

Resolution

  1. Configure the Hardware RAID Controller: Before provisioning the tiering device in ESXi, use the vendor-specific management tools to create a single logical device from multiple physical NVMe disks.
  2. Identify the Logical Device UID: Connect to the ESXi host via SSH and run the following command to find the Device UID for the RAID volume: esxcli storage core adapter device list Example Output: vmhba1 t10.VMDRAID_Intel_Raid_1_VolumeVolume000000001
  3. Create the Tiering Device: Run the creation command using the path to the RAID volume: esxcli system tierdevice create -d /vmfs/devices/disks/<DEVICE_UID> Note: Acknowledge the "performance maybe degraded" warning if it appears.
  4. Verify the Configuration: Confirm the device is active in the tiering list: esxcli system tierdevice list The output will display the DeviceName, PartitionId, and sector ranges.

Additional Information