The Symantec Messaging Gateway (SMG) appliance fails to boot properly. During the startup sequence, the boot process halts and displays multiple dependency and timeout errors related to the file system.
Because the system cannot mount the necessary local file systems, it fails to load the OS fully. Additionally, administrators are unable to perform local command-line troubleshooting because console access is restricted.
When observing the boot sequence via the console, the system outputs the following errors:
Timed out waiting for device dev-di ######Dependency failed for File System #####Dependency failed for /data.Dependency failed for Local File Systems.Cannot open access to console, the root account is locked.
These symptoms strongly indicate a hardware-level failure, most likely involving the physical hard drive(s) or the RAID controller managing the storage array where the /data partition resides. When the hardware fails to initialize or respond, the operating system times out while trying to mount the drives, leading to a cascade of dependency failures.
Collect serial number and model for problamtic hardware asset. Contact Broadcom Support for assistance.