vSAN Cluster Partition and iSCSI Disruption Due to Continuous TOR Switch Reboots
search cancel

vSAN Cluster Partition and iSCSI Disruption Due to Continuous TOR Switch Reboots

book

Article ID: 439695

calendar_today

Updated On:

Products

VMware vSAN VMware vSphere ESXi

Issue/Introduction

Symptoms

  • The vSAN cluster experiences a network partition where multiple ESXi hosts report a Sub-Cluster Member Count of 1.
  • Virtual Machines (VMs) become unresponsive or inaccessible.
  • Connected iSCSI targets experience connectivity loss or timeouts.
  • vSAN Skyline Health reports critical errors for vSAN Cluster Partition and vSAN: Basic (unicast) connectivity check.
  • Physical uplinks on the ESXi host may intermittently show a state of "Up," but vSAN traffic is not flowing correctly.

Environment

VMware vSAN 8.x

 

Cause

  • The issue is triggered by a physical layer failure where a Top-of-Rack (TOR) switch enters a continuous reboot cycle.
  • In environments configured with multiple active uplinks (e.g., vmnic3 and vmnic6) using the Route Based on Virtual Port ID teaming policy, the constant "flapping" of the link connected to the rebooting switch introduces rapid state changes in the vSAN Cluster Monitoring, Membership, and Directory Service (CMMDS). These frequent updates prevent the cluster from reaching a stable quorum, resulting in the isolation of hosts (node count of 1) and subsequent storage disruption.
  • Review vSAN Logs: Inspect /var/run/log/vsansystem.log for rapid membership fluctuations:

2026-04-21T02:47:25.442Z In(166) vsansystem[2103497]: [vSAN@6876 sub=VsanSystemProvider opId=CMMDSMembershipUpdate-88e6] Complete, nodeCount: 1, runtime info:    (vim.vsan.host.VsanRuntimeInfo) {
2026-04-21T02:48:47.924Z In(166) vsansystem[15550697]:[vSAN@6876 sub=VsanSystemProvider opId=317633f7-893f] Complete, cluster: 5#######-0###-3###-0###-0###########, nodeCount: 1, status: (vim.vsan.host.ClusterStatus)

Review VMkernel Logs: Check /var/run/log/vmkernel.log for NIC link-down events and heartbeat failures:

2026-04-21T02:30:59.159Z In(182) vmkernel: cpu59:2098263)bnxtnet: bnxtnet_display_link:2979: [vmnic# : 0x############] NIC Link is down

2026-04-21T03:22:29.078Z In(182) vmkernel: cpu70:2098263)bnxtnet: bnxtnet_display_link:2979: [vmnic# : 0x############] NIC Link is down

 

 

Resolution

Engage your hardware/network vendor to troubleshoot and resolve the underlying TOR switch reboot cycle.

Do not restore the uplink to Active status until the physical infrastructure is confirmed stable.