NSX manager log indicates 'No northbound connectivity from the edge.'
/var/log/phonehome-coordinator/phonehome-coordinator.log#### ERROR pool-87-thread-4 MonitoringServiceImpl 76063 MONITORING [nsx@6876 alarmId="4f254bbf-a5c9-####-####-d7f147fbc036" alarmState="OPEN" comp="nsx-manager" entId="dcf130f8-####-####-8dac-bbe4ea426ae7" errorCode="MP701099" eventFeatureName="routing" eventSev="HIGH" eventState="On" eventType="routing_down" level="ERROR" nodeId="dc7dc775-####-44f7-####-6b2e1b76bbc9" subcomp="monitoring"] No northbound connectivity from the edge.
NSX Edge log edge/logical_topology shows 'Routing Down'
Edge node========= UUID: d##d.*b##9 / status: Up (Routing Down) MGMT 10.#.#.# / VTEP 10.#.#.#
Loss of all tunnels events: (none) Max BFD rx packet gap: 1001 ms @ ##-##-## ##:##:##
peer edge f##8.*5##a --> (mgm BFD) Up/Up tx/rx: 450/44510.#.#.# --> (tun BFD) Up/Up tx/rx: 447/44810.#.#.#
Topology and HA=============== T0 SR 93##.*##74 (A/S | Preemptive | rank 0 | Down, Routing Down)
VMware NSX
Northbound routing from the NSX Edge is unavailable. All upstream BGP peering sessions are currently in a down state, and no egress static routes are configured to reach the physical network.
Diagnose and restore northbound connectivity (BGP or Static routes) between NSX edge and the uplink router.