Applications hosted in VCD experience continuous reboot loops during rebuild operations
search cancel

Applications hosted in VCD experience continuous reboot loops during rebuild operations

book

Article ID: 439500

calendar_today

Updated On:

Products

VMware Cloud Director VMware Telco Cloud Platform

Issue/Introduction

  • Hosted applications managed by third-party orchestrators enter continuous reboot loops during rebuildOS operations.
  • VMs are assigned duplicate IP addresses by vCenter or fail to present vNIC hardware to the Guest OS after reboot.
  • High frequency of recomposeVApp requests is observed in VCD debug logs.
  • Infrastructure stress leads to applyDVPortgroup task failures and DvsOperationBulkFault errors in vpxd.log.
  • Host agent latencies and RPC timeouts occur with status code 3, returning Null responses for MoDvSwitch calls.

Environment

  • VCD: 10.x
  • TCP: 3, 4.x, 4.0.1, 5.x, 5.0. 5.0.1, 5.0.2

Cause

  • A configuration or password mismatch between the tenant application layer and the VCD infrastructure triggers an automated reconciliation loop from the third-party orchestrator.
  • High-frequency API calls create a race condition that overwhelms the management plane and prevents network state synchronisation across cluster members.

Resolution

  • Take a full backup of the VCD environment and database prior to applying changes.
  • Verify alignment between the orchestrator database and the VCD actual state before maintenance activities.
  • Temporarily disable orchestrator self-healing logic during major infrastructure changes to prevent automated reconciliation loops.
  • Synchronize the orchestrator database with the VCD actual state prior to triggering rebuild operations.
  • If an active conflict exists, manually realign IP addresses in the tenant layer to match the expected orchestrator state to restore immediate stability.