Cannot Clear UIM Alarms in DXO2 (Alarm with given ID not found).
search cancel

Cannot Clear UIM Alarms in DXO2 (Alarm with given ID not found).

book

Article ID: 439207

calendar_today

Updated On:

Products

DX APM SaaS DX Application Performance Management DX OI SaaS DX Operational Intelligence DX Operational Observability DX SaaS

Issue/Introduction

When UIM has been found down users are unable to manually clear DX UIM alarms from within the DX Operational Intelligence (DX OI / DXO2) interface. Attempting to clear the alarms results in the following API error:

Failure:404 : {<EOL> "status" : 404,<EOL> "errorCode" : "404 NOT_FOUND",<EOL> "errorMsg" : "Alarm with given ID not found.",<EOL> "errorDetail" : "",<EOL> "timestamp" : "2026-02-27T08:14+0000"<EOL>}

Because users cannot manually clear these alerts, the alarms may appear to accumulate in DX OI, causing user confusion.

Administrators may notice that disabling and re-enabling the southbound integration clears the alarms, but this is a disruptive workaround that is difficult to justify to end-users.

Cause

DE668765 - When the UIM is down due to some reason, it is possible that connector missed to send the closed notification to DXO2. This behavior is in line with design and working as expected.

Allowing end-users to manually clear UIM-originated alerts directly within the DX OI interface would cause state inconsistencies between the source system (DX UIM) and DX OI. To maintain data integrity, DX UIM must act as the source of truth for its native alarms.

Resolution

No software fix or permanent configuration change is required, as the system is functioning as intended to protect data consistency.

To manage and clear these alarms, utilize the following intended methods:

  • Automatic Reconciliation (Recommended): The system relies on an automated reconciliation process. Over time, this process will run in the background, identify alerts that have been resolved in UIM, and automatically clear the corresponding alerts in DX OI. Users should be advised to wait for this sync to occur.
  • Manual Full Sync: If a situation arises where alarms are causing significant clutter and cannot wait for the standard automatic reconciliation cycle, administrators have the option to trigger a Full Sync directly on the UIM connector. This forces an immediate update of alarm states from UIM to DXO2.

Administrator Note: Disabling and re-enabling the southbound integration to clear alarms is not a recommended standard operating procedure. Always use the connector's Full Sync feature if an immediate manual update is required.

For detatils about all alarms actions refer to documentation.