Failed to promote replica devices.
search cancel

Failed to promote replica devices.

book

Article ID: 438615

calendar_today

Updated On:

Products

VMware Live Recovery

Issue/Introduction

Message appears in Step 13 of Recovery plan:

Failed to promote replica devices. Timed out (300 seconds) while waiting for SRA to complete failover command

Environment

VMware Live Site Recovery 9.0.2

Cause

The warning points to a communication issue with SRA,  updating tasks on the storage side.

Resolution

It would be recommended to look into the following:

  • Check the VLSR advanced settings parameter Site Pair >storage> storage.commandTimeout. Increase to 600,900 accordingly.

  • Rescan the SRA storage devices.

  • Check the Network Time Protocol settings across the appliances to ensure that they are matching.

  • Re-deploy the SRA in VLSR VAMI.