In VMware Cloud Foundation (VCF) environments utilizing vSphere Kubernetes Service (VKS) and NSX over VPC, the Supervisor cluster fails to communicate with the Guest cluster control plane. This symptom is observed when the Supervisor cluster is configured in a standard VPC and the Guest cluster is deployed in a separate VPC using an Aria Automation (VCFA) workflow.
VMware Cloud Foundation 9.0.2
VMware NSX
The External IP Blocks CIDR assigned to the Namespace by the VCFA workflow lacks sufficient capacity, causing both the Supervisor Private (VPC) CIDR and Guest cluster Private (VPC) CIDR to be Network Address Translated (NAT) to the exact same external IP address on the NSX Edge. This overlap breaks inter-VPC bidirectional routing.
This is a condition that may occur in a VMware NSX environment.
Workaround:
Access the Orchestration / Management Plane:
Log in to the vSphere Client for the vCenter Server managing the Workload Management (Supervisor) deployment.
Navigate to Namespace Configurations:
From the vSphere Client home menu, select Workload Management.
Click the Namespaces tab.
Locate the Target Namespace:
Identify the specific vSphere Namespace provisioned by the Aria Automation (VCFA) workflow for the Guest cluster deployment.
Modify Namespace Network Settings:
Access the network settings for the targeted namespace.
Adjust the Egress CIDR (used for SNAT) to utilize an expanded or corrected subnet range that provides sufficient discrete IP addresses, ensuring it does not overlap with the Supervisor's external IP block.
Architectural Note: If the environment strictly utilizes VCFA for VPC creation, you must update the custom VPC Connectivity Profile within Aria Automation to define distinct External IP Blocks before redeploying or syncing the namespace configuration. Refer to Secure vSphere Supervisor API for details on custom VPC Connectivity Profiles.
Validate NSX NAT Rule Allocation:
Log in to the NSX Manager UI.
Navigate to Networking > NAT.
Select the respective VPC Gateway or Tier-1 Gateway associated with the Supervisor and Guest clusters.
Inspect the SNAT rules. Confirm that the rules translating the Supervisor Private (VPC) CIDR and the Guest cluster Private (VPC) CIDR now assign entirely distinct external IP addresses.
Verify Control Plane Connectivity:
Initiate a connection test from the Supervisor nodes to the Guest cluster control plane endpoint (TCP port 6443) to confirm that bidirectional inter-VPC routing is successfully restored.