vSAN Stretched Cluster Host Maintenance Mode Stuck at 87 Percent Due to Asymmetric Fault Domains
search cancel

vSAN Stretched Cluster Host Maintenance Mode Stuck at 87 Percent Due to Asymmetric Fault Domains

book

Article ID: 438165

calendar_today

Updated On:

Products

VMware vSAN

Issue/Introduction

  • In a VMware vSAN Stretched Cluster environment, placing an ESXi host into maintenance mode fails or permanently stalls. 
  • The vCenter Server Recent Tasks pane shows the "Enter Maintenance Mode" task stuck at exactly 87%.
  • Stretched Cluster is running with different amount of hosts in each Fault Domain.

The /var/run/log/clomd.log on the affected host or vSAN cluster nodes displays the following error indicating a failure to balance quorum votes in lower (site) Fault Domain:

2026-04-23T12:27:13.373Z No(29) clomd: [Originator@6876 opID=<REDACTED_SECRETS>] CLOMSetQuorumVotes: Counted votes good:4, absent:0, bad:0; upperFDs:2, minLowerFDs:2, nTotalReplicas:4, nUpperReplicas:2, nLowerReplicas:2
2026-04-23T12:27:13.373Z No(29) clomd: [Originator@6876 opID=<REDACTED_SECRETS>] CLOMSetQuorumVotes: 1 upper primary witnesses are required
2026-04-23T12:27:13.373Z No(29) clomd: [Originator@6876 opID=<REDACTED_SECRETS>] CLOMSetQuorumVotes: Need at least 3 Lower FDs Per Upper, current: 2
2026-04-23T12:27:13.373Z No(29) clomd: [Originator@6876 opID=<REDACTED_SECRETS>] SetVotes: Balance votes - twoLevelVoteAssignment: TRUE minimalVotesPerUpper:3

 

 

Environment

VMware vSphere vSAN

Cause

The maintenance mode data evacuation is failing due to an asymmetric host distribution across the vSAN Stretched Cluster Fault Domains (e.g., 4 hosts in the Primary site and 3 hosts in the Secondary site). The Cluster Level Object Manager (CLOM) fails to recalculate the nested quorum votes required to satisfy the lower (within site) Storage Policy because the Secondary site does not possess enough lower Fault Domains (hosts) to balance against the Primary site.

Resolution

Ensure that smaller site does have enough nodes to satisfy 'Failures to tolerate' rule of Storage Policy for desired Maintenance Mode. This can be achieved by:

- adding additional vSAN-enabled ESXi host to a smaller site, or:
- reconfiguring Storage Policy to one with lower host requirement, one able to satisfy desired data evacuation modes within smaller site. 

NOTE: Storage Policy reconfiguration should not used as ad-hoc solution - as it requires careful planning, may involve storage usage increase and may involve significant amount of resync temporarily. 

Additional Information

vSAN Stretched Cluster Guide