Host Redundancy Lost" as below:Hosts > Configure > Storage Adapters > Network Port Binding > iSCSI VMkernel adapters with status 'Not Used' or 'Last Active' instead of Active.VMware vSphere ESXi 8.x
The issue occurred because iSCSI port binding was configured across different subnets. Port binding is only for paths on the same subnet, and mixing subnets causes connection failures and path issues.
From ESXi, var/run/log/vobd.log, there is an event with "iscsi initiator could not establish network connection with vmk"2026-04-14T08:31:03.843Z In(14) vobd[2097861]: [iscsiCorrelator] 237500712180us: [vob.iscsi.target.connect.error] vmhba64 @ vmk2 failed to login to iqn.199X-##.com.######:######################## because of a network connection failure.2026-04-14T08:31:03.845Z In(14) vobd[2097861]: [iscsiCorrelator] 237500714201us: [vob.iscsi.target.connect.error] vmhba64 @ vmk1 failed to login to iqn.199X-##.com.######:######################## because of a network connection failure.2026-04-14T08:31:03.845Z In(14) vobd[2097861]: [iscsiCorrelator] 237521705350us: [esx.problem.storage.iscsi.target.connect.error] Login to iSCSI target iqn.199X-##.com.######:####################### on vmhba64 @ vmk1 failed. The iSCSI initiator could not establish a network connection to the target.
Recommend to remove iSCSI port binding from the ESXi storage adapter settings, as port binding is supported only within the same subnet and breaks multi-path routing across different subnets.
For more details - Considerations for using software iSCSI port binding in ESXi