An NSX Manager upgrade dry run failure is observed during prechecks.
The system displays an error stating the upgrade dry run failed.The prompt advises against proceeding with the upgrade.A support bundle collection is requested for VMware GS.The failed migration is explicitly listed as Migrating OwnershipMigrationTask.
Active alarms are concurrently observed on the NSX Manager.
VMware NSX
Memory and disk space exhaustion are identified as one of the causes for this alarm.
High utilization within the root or nonconfig partitions triggers the precheck failure.
It is imperative to clear the active disk space alarms on the NSX Manager prior to retrying the upgrade.
Below are some of the known disk space exhaustion frequently faced in NSX 3.X
Follow the remediation steps in article 322585 to clear high root partition usage.
Refer to article 401173 to address high utilization on the nonconfig partition.
Execute the instructions in article 417465 if the nonconfig partition is completely full.
Re-run the upgrade coordinator prechecks once the partitions are cleared and alarms are resolved.