Prompt User Settings Disappear from Software Delivery Jobs
search cancel

Prompt User Settings Disappear from Software Delivery Jobs

book

Article ID: 437553

calendar_today

Updated On:

Products

CA Client Automation - IT Client Manager CA Client Automation

Issue/Introduction

In Client Automation 14.6, when users try to execute a Software Deliver job with "Prompt user" settings in an unsealed job, the settings do not persist. 

These settings exist in the Properties /Setup jobs Window of the Software Delivery job under the jobs tab. 

Affected Settings

  • Prompt user. (Windows Only) 
    • Allow user to cancel the jobs
    • Execute jobs if prompt times out

When users try to renew a failed SD job, some the SD Job options above are reset.

Example : Boot level, prompt user, Run jobs off-line from Scalability Servers

If Job Linkage is set to "Batch job execution", "Allow user to cancel the jobs" or "Execute jobs if prompt times out" could not be selected

If 'Activate at" date/time is changed, and if Job Linkage is changed (ex: from "No linkage" to "Batch job execution") the "Activate at" value is reset to default value

After applying these settings, and coming back to the same section users will see that the settings do not persist and become unchecked.

Environment

Client Automation 14.6

Cause

This bug in Client Automation 14.6 and prevents users from correctly saving user prompt settings in unsealed containers. 

Resolution

As a workaround, you can:

  1. Navigate to the job Properties Window Job Containers tab
  2. Select "Seal and evaluate Job Container"
  3. With this active, the Prompt User settings will persist.

There is a hotfix ID T533413 that has been confirmed to fix this issue.

This fix delivers the file gui_sd.dll:

Name    : gui_sd.dll
Size    : 1 963 904 bytes
Date    : 14 April 2026
Version : 14.6.0.105

Install this fix on the Domain Manager and Remote DSM Explorer 14.6

This fix is expected to be released in in 14.6 CU1.

If you need this fixed sooner, then please open a new case with Broadcom Support and request the hotfix.