NSX inventory containers are empty after Antrea interworking pod deployment
book
Article ID: 437176
calendar_today
Updated On:
Products
VMware NSXVMware vSphere ESXi
Issue/Introduction
NSX inventory (NSX -> inventory -> containers) is empty despite a successful Antrea integration deployment.
Antrea interworking pod remains in error state.
Antrea interworking tn-proxy log has NSX Manager connection timeout errors.
Couldn't connect to 'ssl://[IP_ADDRESS]:1234' (error: 110-Connection timed out)"
Environment
Antrea-NSX Integration
vSphere Kubernetes Service (VKS)
Cause
The physical network blocks traffic to the individual physical IPs of the NSX Manager cluster members on Port 1234.
Resolution
Identify all IPs associated with the NSX Manager cluster nodes.
Configure physical firewall rules to permit bidirectional traffic on TCP Port 1234/1235/443 between the Kubernetes cluster CIDR and all individual NSX Manager node IPs