After upgrading to Windows Sensor version 7.5.0, some endpoints may stop reporting event data to the console.
Symptoms:
Local event backlog growth on the sensor.
Sensors appear "Online" but fail to offload event logs.
SensorComms.log records repeated 403 Forbidden errors.
Example Log Error:
[V] [data/eventlog/reserve] failed with HRESULT 0x80190193 (403 Forbidden)This issue is caused by a defect in a newly introduced connection fallback mechanism. The bug is specifically triggered in environments with unstable or inefficient network conditions.
When a transient DNS failure or a brief network glitch occurs, the sensor incorrectly triggers its fallback logic. Instead of retrying the connection to the assigned Minion Node, it incorrectly routes event traffic to the Primary Node (N0) using the LastKnownGoodServerName. Since the Primary Node is not authorized to accept event data (which is a role reserved for Minion Nodes), it rejects the request with a 403 Forbidden status.
Once the sensor enters this "fallback" state, the connection becomes sticky, meaning it will continue to target the wrong node even after the network recovers.
A permanent fix is being incorporated into the upcoming Windows Sensor version 7.5.1.
If the event backlog is causing critical data visibility gaps or impacting production stability, please contact Broadcom Support
If an immediate upgrade or hotfix is not feasible, the following workaround can be used to restore connectivity:
Restart the Sensor Service: Manually restarting the Carbon Black Sensor service clears the incorrect fallback cache and forces the sensor to re-resolve the correct Minion FQDN. Note that the issue may recur if the network experiences further instability.